Figure 1 describes the geometry and loadings for the double
corbel structure being considered. The
thickness of the corbel is 600 mm. The concrete strength is 35 MPa, and the
yield strength of reinforcement is taken as 420 MPa. The corbel supports an
ultimate vertical force of 1000 kN and an ultimate horizontal force of 100 kN
at each end and two ultimate point loads of 3000 kN in the supporting column
region. Bearing plates of 150 mm length x 600 mm width x 25 mm thick are provided at each end
of the corbel. Figure 2 shows the selected strut-and-tie model for this
structure. The design will be completed to meet ACI 318-02 Appendix A
requirements.
Figure 1 The Geometry and the Loadings of the Corbel under Consideration
Figure 2 Strut-and-Tie Model Employed in this Corbel Design

|